SmartHarmo™ brings together the energy-saving power of variable frequency drives (VFDs) and advanced harmonic mitigation. The result: more efficient vessel operations while helping protect generators, transformers and motors.

Request Technical Brief
SmartHarmo marine energy-saving VFD and harmonic mitigation cabinet
Savings
50–58%
THDi
3–8%
Payback
8–16 mo

The Challenge: Hidden Energy Losses and Harmonic Stress

Marine vessels can lose valuable energy through unoptimised engine-cooling seawater pumps, diesel generator overconsumption and mismatched engine-room motors. Traditional VFD upgrades may not deliver the fuel savings you expect, while the harmonic currents they generate stress shipboard electrical infrastructure.

On a typical container vessel, standard six-pulse VFDs produce 35–45% current distortion (THDi) at rated load, and even more at partial loads—causing IEEE 519 violations, generator derating of 15–25%, and transformer derating of 20–24%.

Motor and Generator Core Damage

Excessive harmonic currents increase eddy-current and hysteresis losses, overheating stator and rotor cores.

Interwinding Faults

Voltage distortion and high dv/dt stress accelerate insulation degradation across motor and transformer windings.

Reduced Bearing Life

High-frequency shaft currents induced by unmitigated VFDs cause premature bearing pitting and mechanical failure.

The SmartHarmo™ Solution

Combines VFD-driven efficiency with advanced harmonic mitigation in a single energy-efficiency system that intelligently controls auxiliary machinery.

01

Dynamic Flow Optimisation

Continuously adjusts pump speed to match real-time cooling system demand.

02

Temperature-Differential Mode

Modulates seawater flow precisely according to temperature differentials across cooling circuits.

03

Best Efficiency Point (BEP) Tracking

Keeps pump operating efficiency at its peak even under partial-load sea conditions.

04

Self-Adjusting Control

Automatically adapts control curves to the hydraulic characteristics of each shipboard system.

Engineering Comparison

Technical Specifications

Direct performance comparison between SmartHarmo™ and a conventional six-pulse marine VFD.

ParameterSmartHarmo™Traditional VFD
Current distortion (THDi)3–8%35–45%
Displacement power factor0.96–0.990.75–0.85
Distortion power factor0.85–0.92—
Generator derating3–8% (0% in comparison case)15–25%
Transformer derating5–12%20–24%
Harmonic filteringActive and passive options—
MonitoringReal-time power qualityNo real-time optimisation
Typical payback8–16 months—

Key Benefits for Your Vessel

Proven Energy Savings

50–58% energy savings demonstrated on engine-cooling seawater pumps.

Faster ROI

Typical capital payback achieved in 8–16 months of sea-going operation.

Lower Emissions

Significant reductions in CO2, SOx and NOx through reduced auxiliary generator load.

Recovered Capacity

Reclaims generator and transformer capacity otherwise lost to harmonic derating.

Greater Reliability

Reduces thermal and electrical stress on generators, transformers and motors.

Improved Performance

Optimised auxiliary machinery performance across varying sea-going profiles.

Future-Ready Compliance

Supports IEEE 519, marine class rules, and evolving emissions regulations.

Scalable Solution

Tailored to the specific electrical topology and load profile of your vessel.

Evaluate SmartHarmo™ for Your Vessel

Request a tailored harmonic audit and seawater pump energy-savings projection from our Singapore engineering team.